Pitco Frialator VF35 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
5
L20-418 Rev 0 9/13
INSTALLATION
Checking And Unpacking Your New Appliance
Your new Pitco appliance has been carefully packed into one crate. Every effort has been made to ensure that it is
delivered to you in perfect condition. Pitco does not assume responsibility for damage or loss incurred in transit.
1. Upon Delivery, inspect for visible shipping damage in the presence of the trucking operator. If something appears
damaged, file a claim for damages regardless of extent.
2. Unpack and inspect unit for damage. Contact the shipper within 15 days and file a concealed damage claim; the
shipper is only responsible for concealed damage for 15 days after delivery.
3. Remove the unit from the shipping pallet:
a: Remove the filter pan, and JIB pan from unit before attempting to
dismount the unit from the shipping base.
4. Do not allow the full weight of the unit to rest on the legs or caster when removing the appliance from the shipping
pallet. The casters can be bent or damaged if too much weight or force is applied to them from improper handling.
5. Check the packing list enclosed with your appliance to ensure that you have received all the parts to the
appliance. If you are missing any parts, contact the dealer from whom the appliance was purchased.
6. Using the front cover of this manual, record the following for warranty service or future reference: 1. Your Pitco
model number. 2. Fryer serial numbers (Found on the inner door of each fryer). 3. The date purchased from
your dealer invoice.
Once you have completed the above, the appliance is ready to be installed.
Installation Clearances
The clearances shown below are for combustible and non-combustible installations and will allow for safe and proper
operation of your appliance.
In addition to the above clearances there must also be at least 30 inches (76.2cm) of aisle space in front of the unit.
Combustible Construction Non Combustible Construction
Inches (centimeters) Inches (centimeters)
Back
6.0" (15.2cm) 0.0" (0.0cm)
Sides
6.0" (15.2cm) 0.0" (0.0cm)
Floor
9” (22.86 cm) 9” (22.86 cm)
WARNING
DO NOT obstruct the flow of ventilation air openings around the appliance. Adequate clearance around the appliance is
necessary for servicing and proper component ventilation. Ensure that you meet the minimum clearance requirements
specified in this manual.
WARNING
DO NOT install this appliance next to a water cooker, or use in any way in which water can come in contact with the hot
oil. Splash over of water into hot oil may result in a steam eruption, potentially causing hot oil to be ejected from the
fryer, and creating a burn hazard.